We use cookies to give you the best possible service. By using the website, you agree to our privacy policy.  > Read more

Air heat pump 22-56 kW

EcoTouch Air Kaskade (Power Inverter) | Air water heat pump

Hot water Ventilation Cooling Heating Solar
EcoTouch Air Kaskade (Power Inverter) - Air heat pump 22-56 kW +
  • Refrigerant R410A, filled up to 10 m lead
  • Compressor: Scroll,  suction gas colled, inverter technology
  • Defrosting: reversal operation
  • Cooling operation: reversal operation, automatic (dependent of need)
  • Hydraulic: filling pressure-manometer, protection ventil
  • Cryogenic connection: int.-/ext. modul: pipe 10 x 1 und 16 x 1, copper in cooling quality.
  • DIN EN 12735-1. Lokring installations set included in delivery

General description
The heat source of EcoTouch Air Kaskade is the air. The unit offers a complete solution for a power demand to 56 kW in split construction. With the power inverter technology the compressor power adapts itself ioptimal to the required heat need. Achievement area: 22 to 56 kW.

The variations
Different indoor modules (in white high gloss or stainless steel look) are combinable with outdoor modules in "Zubadan technology": EcoTouch Air Kaskade, only heating, no domestic hot water heasting,  cascadable up to 56 kW.

+
Item number
ETAIK2250
Persons
8
Flow temperature up to A-20
50 °C
Power consumption input A-7/W35
5.8 kW
Power consumption output A-7/W35
17 kW
Power consumption
A2/W35
Power consumption input
4.4 kW
Power consumption output
16 kW
Cooling capacity
18.2 kW
Cooling capacity Add
A35/W7
COP EN14511 A-7/W35
2.89
Heatingwater flow rate
3.8 m³/h (Δt=5K)
Air flow rate max
13200 m³/h
Rolling piston inverter
Scroll-Inverter
Operating limit
A-15/W50, A-10/W55, A2/W60
Weight outdoor unit
270 kg
Weight indoor unit
200 kg
Dimensions indoor unit
750 x 1470 x 611 B x H x T mm
Dimension outdoor unit
950 x 1350 x 330 B x H x T mm
Connections heat source/use
16/10 / 2 inch ext. flat-sealing
Refrigerant
R410A
Reversible
reversibel
+
Item number
ETAIK2850
Persons
8
Flow temperature up to A-20
50 °C
Power consumption input A-7/W35
7.7 kW
Power consumption output A-7/W35
22.2 kW
Power consumption
A2/W35
Power consumption input
5.3 kW
Power consumption output
19.2 kW
Cooling capacity
25 kW
Cooling capacity Add
A35/W7
COP EN14511 A-7/W35
2.90
Heatingwater flow rate
4.8 m³/h (Δt=5K)
Air flow rate max
13200 m³/h
Rolling piston inverter
Scroll-Inverter
Operating limit
A-15/W50, A-10/W55, A2/W60
Weight outdoor unit
270 kg
Weight indoor unit
200 kg
Dimensions indoor unit
750 x 1470 x 611 B x H x T mm
Dimension outdoor unit
950 x 1350 x 330 B x H x T mm
Connections heat source/use
16/10 / 2 inch ext. flat-sealing
Refrigerant
R410A
Reversible
reversibel
+
Item number
ETAIK3350
Persons
8
Flow temperature up to A-20
50 °C
Power consumption input A-7/W35
8.8 kW
Power consumption output A-7/W35
25.5 kW
Power consumption
A2/W35
Power consumption input
6.6 kW
Power consumption output
24 kW
Cooling capacity
27.3 kW
Cooling capacity Add
A35/W7
COP EN14511 A-7/W35
2.90
Heatingwater flow rate
5.7 m³/h (Δt=5K)
Air flow rate max
19800 m³/h
Rolling piston inverter
Scroll-Inverter
Operating limit
A-15/W50, A-10/W55, A2/W60
Weight outdoor unit
405 kg
Weight indoor unit
220 kg
Dimensions indoor unit
750 x 1470 x 611 B x H x T mm
Dimension outdoor unit
950 x 1350 x 330 B x H x T mm
Connections heat source/use
16/10 / 2 inch flat-sealing
Refrigerant
R410A
Reversible
reversibel
+
Item number
ETAIK4250
Persons
8
Flow temperature up to A-20
50 °C
Power consumption input A-7/W35
11.6 kW
Power consumption output A-7/W35
33.6 kW
Power consumption
A2/W35
Power consumption input
8 kW
Power consumption output
28.8 kW
Cooling capacity
37.5 kW
Cooling capacity Add
A35/W7
COP EN14511 A-7/W35
2.90
Heatingwater flow rate
7.2 m³/h (Δt=5K)
Air flow rate max
19800 m³/h
Rolling piston inverter
Scroll-Inverter
Operating limit
A-15/W50, A-10/W55, A2/W60
Weight outdoor unit
405 kg
Weight indoor unit
220 kg
Dimensions indoor unit
750 x 1470 x 611 B x H x T mm
Dimension outdoor unit
950 x 1350 x 330 B x H x T mm
Connections heat source/use
16/10 / 2 inch ext. flat-sealing
Refrigerant
R410A
Reversible
reversibel
+
Item number
ETAIK5650
Persons
8
Flow temperature up to A-20
50 °C
Power consumption input A-7/W35
15.4 kW
Power consumption output A-7/W35
44.8 kW
Power consumption
A2/W35
Power consumption input
10.7 kW
Power consumption output
38.4 kW
Cooling capacity
50 kW
Cooling capacity Add
A35/W7
COP EN14511 A-7/W35
2.90
Heatingwater flow rate
9.6 m³/h (Δt=5K)
Air flow rate max
26400 m³/h
Rolling piston inverter
Scroll-Inverter
Operating limit
A-15/W50, A-10/W55, A2/W60
Weight outdoor unit
540 kg
Weight indoor unit
240 kg
Dimensions indoor unit
750 x 1470 x 611 B x H x T mm
Dimension outdoor unit
950 x 1350 x 330 B x H x T mm
Connections heat source/use
16/10 / 2 inch ext. flat-sealing
Refrigerant
R410A
Reversible
reversibel

Services

Contact to Waterkotte

Send us your question.

Personal Guidance

Waterkotte Contact Person