We use cookies to give you the best possible service. By using the website, you agree to our privacy policy.  > Read more

Air heat pump 6-12 kW

Basic Line BM 7010 | Air water heat pump

Hot water Ventilation Cooling Heating Solar
Basic Line BM 7010 - Air heat pump 6-12 kW +
  • Ready to use, tested heat pump unit
  • Chlorine-free refrigerant R410A without ozone depletion
  • Design optimised for transport and installation
  • Special insulation for noise reduction
  • Easy to service unit design
  • Weather-resistant housing
  • Speed-controlled fans
  • Speed-controlled rolling piston inverter
  • Electronically-controlled expansion valves
  • Defrosting process: Circulation reversal using 4-way valve
  • Special pipe routing in the evaporator to avoid icing
  • Active cooling due to reversing refrigerant circulation
  • Liquid separator in the refrigerant circulation for maximum reliability
  • Connections installed on rear
  • Unit dimensions: (W x H x D mm) 1200 x 1250 x 400
  • Reduced space requirement 0.5 m2

  • WebInterface BN Web
  • Hot water tank EcoStock
  • Optionally:

    • Control module BM Mod 5010
    • Hydraulic module BM Hyd 5010

  • Low operating costs due to COP values up to 4.8
  • Little space required for outdoor unit
  • Little space required for heating system
  • Range of options
  • Straightforward, quick installation

For winter and summer
The newly developed Basic Line BM 7010 was designed
as a compact air source heat pump for outdoor installation.
The Monoblock is suitable for heating and cooling
low-energy buildings.

Efficient and powerful
Thanks to the inverter-controlled compressor, the BM
7010 operates extremely energy-efficiently. Due to the
infinitely variable adjustment of the power it impresses
with high performance. Even at outdoor temperatures of
-15 °C, flow temperatures of 55° C are possible.

Control technology of your choice
The outdoor unit contains all the heat pump technology.
Only the wall-mounted control module BM Mod 5010 or,
optionally, the innovative hydraulic module BM Hyd 5010
is installed in the building.

Hardly a sound
The high-quality housing has special noise insulation. In
this way the noise emissions are reduced to a minimum.
The outdoor unit can be installed quickly and straightforwardly.
The installer does not need to be a qualified
refrigeration specialist.

+
Item number
MB701059
Persons
8
Flow temperature up to A-20
45 °C
Power consumption input A-7/W35
2.8 kW
Power consumption output A-7/W35
7.1 kW
Power consumption
A2/W35
Power consumption input
2.8 kW
Power consumption output
10.8 kW
Cooling capacity
7.8 kW
Cooling capacity Add
A35/W7
COP EN14511 A-7/W35
2.60
Heatingwater flow rate
1.4 m³/h (Δt=5K)
Air flow rate max
7000 m³/h
Rolling piston inverter
Inverter rotary compressor
Sound pressure level
43 dB(A)
Operating limit
A-15/W45, A-7/W50, A0/W55
Weight outdoor unit
140 kg
Dimension outdoor unit
1250 x 1200 x 400 B x H x T mm
Connections heat source/use
1 1/4 inch
Refrigerant
R410A
Reversible
reversibel
Item number
HM7010C
Power consumption input A-7/W35
2.8 kW
Power consumption output A-7/W35
7.1 kW
Power consumption
A2/W35
Power consumption input
2.8 kW
Power consumption output
10.8 kW
Cooling capacity
7.8 kW
Cooling capacity Add
A35/W7
COP EN14511 A-7/W35
2.60
Air flow rate max
7000 m³/h
Rolling piston inverter
Inverter rotary compressor
Sound pressure level
43 dB(A)
Operating limit
A-15/W45, A-7/W50, A0/W55
Weight outdoor unit
140 kg
Dimensions indoor unit
360 x 400 x 170 B x H x T mm
Dimension outdoor unit
1250 x 1200 x 400 B x H x T mm
Connections heat source/use
1 inch ext. flat-sealing
Refrigerant
R410a
Reversible
reversibel
Item number
HM7010CH
Power consumption input A-7/W35
2.8 kW
Power consumption output A-7/W35
7.1 kW
Power consumption
A2/W35
Power consumption input
2.8 kW
Power consumption output
10.8 kW
Cooling capacity
7.8 kW
Cooling capacity Add
A35/W10
COP EN14511 A-7/W35
2.60
Heatingwater flow rate
1.4 m³/h (Δt=5K)
Air flow rate max
7000 m³/h
Rolling piston inverter
Inverter rotary compressor
Sound pressure level
43 dB(A)
Operating limit
A-15/W45, A-7/W50, A0/W55
Weight outdoor unit
140 kg
Dimensions indoor unit
743 x 750 x 303 B x H x T mm
Dimension outdoor unit
1250 x 1200 x 400 B x H x T mm
Connections heat source/use
1 1/4 inch ext. flat-sealing
Refrigerant
R410a
Reversible
reversibel
Item number
HM7010CHW
Persons
15
Power consumption input A-7/W35
2.8 kW
Power consumption output A-7/W35
7.1 kW
Power consumption
A2/W35
Power consumption input
2.8 kW
Power consumption output
10.8 kW
Cooling capacity
7.8 kW
Cooling capacity Add
A35/W7
Tank capacity min
200 l
Tank capacity max
1000 l
Tank capacity extentable
Yes
COP EN14511 A-7/W35
2.80
Heatingwater flow rate
1.4 m³/h (Δt=5K)
Air flow rate max
7000 m³/h
Rolling piston inverter
Inverter rotary compressor
Sound pressure level
43 dB(A)
Operating limit
A-15/W45, A-7/W50, A0/W55
Weight outdoor unit
140 kg
Dimensions indoor unit
7430 x 750 x 303 B x H x T mm
Dimension outdoor unit
1250 x 1200 x 400 B x H x T mm
Connections heat source/use
1 1/4 inch ext. flat-sealing
Refrigerant
R410a
Reversible
reversibel
Item number
HM7010CHT
Power consumption input A-7/W35
2.8 kW
Power consumption output A-7/W35
7.1 kW
Power consumption
A2/W35
Power consumption input
2.8 kW
Power consumption output
10.8 kW
Cooling capacity
7.8 kW
Cooling capacity Add
A35/W7
COP EN14511 A-7/W35
2.60
Heatingwater flow rate
1.4 m³/h (Δt=5K)
Air flow rate max
7000 m³/h
Rolling piston inverter
Inverter rotary compressor
Sound pressure level
43 dB(A)
Operating limit
A-15/W45, A-7/W50, A0/W55
Weight outdoor unit
140 kg
Dimensions indoor unit
743 x 750 x 303 B x H x T mm
Dimension outdoor unit
1250 x 1200 x 400 B x H x T mm
Connections heat source/use
1 1/4 inch ext. flat-sealing
Refrigerant
R410a
Reversible
reversibel
Item number
HM7010CHWT
Persons
15
Power consumption input A-7/W35
2.8 kW
Power consumption output A-7/W35
7.1 kW
Power consumption
A2/W35
Power consumption input
2.8 kW
Power consumption output
10.8 kW
Cooling capacity
7.8 kW
Cooling capacity Add
A35/W7
Tank capacity min
200 l
Tank capacity max
1000 l
Tank capacity extentable
Yes
COP EN14511 A-7/W35
2.60
Heatingwater flow rate
1.4 m³/h (Δt=5K)
Air flow rate max
7000 m³/h
Rolling piston inverter
Inverter rotary compressor
Sound pressure level
43 dB(A)
Operating limit
A-15/W45, A-7/W50, A0/W55
Weight outdoor unit
140 kg
Dimensions indoor unit
743 x 750 x 303 B x H x T mm
Dimension outdoor unit
1250 x 1200 x 400 B x H x T mm
Connections heat source/use
1 1/4 inch ext. flat-sealing
Refrigerant
R410a
Reversible
reversibel

Services

Contact to Waterkotte

Send us your question.

Personal Guidance

Waterkotte Contact Person